1 00:00:12,828 --> 00:00:15,672 Micrograms to multiple grams. 2 00:00:15,707 --> 00:00:18,400 Highest purity and maximum recovery. 3 00:00:18,450 --> 00:00:21,216 Save time and cut costs. 4 00:00:21,800 --> 00:00:25,623 Agilent solutions can help you do just that. 5 00:00:25,658 --> 00:00:30,103 Instruments. Columns. Software. Services. 6 00:00:30,138 --> 00:00:31,711 Simply everything. 7 00:00:31,746 --> 00:00:35,295 Everything you need to purify your way 8 00:00:37,500 --> 00:00:41,966 The Agilent 218 Purification System has the flexibility 9 00:00:42,001 --> 00:00:46,198 to adapt to your purification needs as they change over time. 10 00:00:46,800 --> 00:00:52,990 Delivering isocratic flow or gradients with excellent precision and reproducibility, 11 00:00:53,025 --> 00:00:59,380 this system meets the day-to-day needs of chemical and pharmaceutical research laboratories 12 00:00:59,415 --> 00:01:01,650 up to gram quantities of product. 13 00:01:01,700 --> 00:01:05,100 What's more, it's within reach of any budget. 14 00:01:06,000 --> 00:01:10,821 Easy-to-change pump heads allow you to span a broad flow range 15 00:01:10,856 --> 00:01:18,401 from as little as 0.025 milliliter to as much as 200 milliliters per minute, depending on the application. 16 00:01:18,436 --> 00:01:25,445 The system's UV-Visible detector has a dynamic detection range up to 80 absorbance units. 17 00:01:25,480 --> 00:01:32,476 This detector's unique dual path-length flow cell maximizes sensitivity for analytical applications 18 00:01:32,511 --> 00:01:36,645 while preventing detector overload during preparative runs. 19 00:01:38,152 --> 00:01:43,083 The Agilent 1260 Infinity Analytical-Scale Purification System 20 00:01:43,150 --> 00:01:48,579 is the solution of choice for highest purity and maximum compound recovery. 21 00:01:48,614 --> 00:01:54,370 Capable of delivering flow rates from 100 microliters to 10 milliliters per minute 22 00:01:54,405 --> 00:01:56,634 at pressures up to 600 bar, 23 00:01:56,669 --> 00:02:03,080 this system is ideal for compound purification in the nanogram to low milligram range 24 00:02:03,115 --> 00:02:08,945 on columns with internal diameters between 2.1 and 9.4 millimeters. 25 00:02:08,980 --> 00:02:14,728 After purification, simply take your collected fraction to your NMR instrument 26 00:02:14,763 --> 00:02:17,100 to confirm the compound's structure. 27 00:02:17,150 --> 00:02:20,871 The system features Agilent's fraction delay sensor technology 28 00:02:20,906 --> 00:02:23,452 that determines delay volumes automatically, 29 00:02:23,487 --> 00:02:27,529 assuring highest purity and recovery of your fractions. 30 00:02:28,000 --> 00:02:31,080 With a completely metal-free flow path, 31 00:02:31,115 --> 00:02:36,328 the Agilent 1260 Infinity Bio-inert LC System with fraction collector 32 00:02:36,363 --> 00:02:39,287 is the perfect solution for protein purification. 33 00:02:41,000 --> 00:02:46,916 The Agilent 1260 Infinity Preparative-scale LC/MS Purification System 34 00:02:46,978 --> 00:02:53,900 offers you ultimate flexibility - use it as a workhorse for automated, high-throughput applications, 35 00:02:54,068 --> 00:02:59,306 or as a method scale-up solution for optimizing resolution and recovery. 36 00:02:59,385 --> 00:03:04,343 The system delivers high flow rates up to 100 mL/min 37 00:03:04,378 --> 00:03:09,103 on columns with internal diameters from 9.4 to 50 mm, 38 00:03:09,138 --> 00:03:14,500 making it ideal for purifying hundreds of milligrams that are typically required 39 00:03:14,550 --> 00:03:17,164 for biological screening of compounds. 40 00:03:18,500 --> 00:03:25,200 The system's modular design offers outstanding flexibility to configure solutions for purification 41 00:03:25,250 --> 00:03:28,636 of micrograms to milligrams of pure product. 42 00:03:29,646 --> 00:03:35,020 Rugged scale-up from an analytical to a preparative configuration with MS detector 43 00:03:35,055 --> 00:03:40,842 and multiple fraction collectors meets the requirements of the most demanding applications. 44 00:03:43,411 --> 00:03:50,600 The Agilent SD-1 Purification System achieves better gradient accuracy over a larger flow rate range 45 00:03:50,650 --> 00:03:53,993 than any other preparative LC system today. 46 00:03:54,028 --> 00:03:58,100 Exchangeable pumps heads enable the system to deliver flow rates 47 00:03:58,150 --> 00:04:03,233 from 0.01 mL up to 500 mL per minute. 48 00:04:03,268 --> 00:04:10,079 One system runs routine analyses and scales-up to multiple gram levels of sample. 49 00:04:11,000 --> 00:04:15,150 With this capability you can develop and apply the purification scheme 50 00:04:15,250 --> 00:04:18,880 for your precious synthetic peptides on a single system. 51 00:04:18,915 --> 00:04:22,000 Scouting runs and preparative runs are possible 52 00:04:22,050 --> 00:04:26,100 by simply switching the flow path - without replumbing the system. 53 00:04:28,500 --> 00:04:36,127 With Agilent OpenLAB CDS you have one simple yet easy-to-use software platform for analysis 54 00:04:36,162 --> 00:04:43,573 and purification with the speed of UHPLC and with the confirmatory power of mass detection. 55 00:04:46,370 --> 00:04:51,824 Agilent Load & Lock Columns are the ideal companion for preparative applications 56 00:04:51,859 --> 00:04:54,705 that require high throughput and high yield. 57 00:04:54,740 --> 00:05:02,606 Available with inside diameters of 1 to 3 inches, these columns combine excellent packed bed stability 58 00:05:02,641 --> 00:05:07,700 with enhanced flow distribution to deliver the highest possible purification quality 59 00:05:07,750 --> 00:05:10,350 with maximum speed and flexibility. 60 00:05:10,500 --> 00:05:15,511 Easy-to-use packing stations allow you to pack any commercially-available media 61 00:05:15,546 --> 00:05:18,621 using dynamic or static axial compression. 62 00:05:18,656 --> 00:05:24,086 Agilent Load & Lock Columns feature unique fluid and sample distribution technology 63 00:05:24,121 --> 00:05:31,725 that increases sample loading by up to 20% while minimizing peak broadening and reducing back pressure. 64 00:05:32,400 --> 00:05:37,508 Purify your way with the most flexible portfolio of reliable solutions 65 00:05:37,543 --> 00:05:41,100 for sample purification by liquid chromatography.