1 00:00:09,400 --> 00:00:13,100 Whether you need to enrich your analytes, remove matrix components, 2 00:00:13,125 --> 00:00:17,000 or lower detection limits for trace-level water analysis, 3 00:00:17,050 --> 00:00:23,131 the highly modular design of the Agilent 1200 Infinity Series Online SPE solutions 4 00:00:23,200 --> 00:00:30,300 provide you with the flexibility to tailor your system to match virtually any analytical LC challenge. 5 00:00:30,600 --> 00:00:36,700 Agilent's online SPE solutions are based on the 1290 Infinity Flexible Cube 6 00:00:36,861 --> 00:00:40,955 that houses up to two valves and re-usable SPE cartridges. 7 00:00:40,990 --> 00:00:47,114 Valve heads are easy to mount on the drives thanks to Agilent's Quick-Change valve technology. 8 00:00:47,149 --> 00:00:51,281 The Flexible Cube also has a built-in piston pump and 9 00:00:51,447 --> 00:00:56,000 a solvent selection valve for conditioning and loading the cartridges. 10 00:00:56,607 --> 00:01:01,736 Combined with Agilent's 6400 Series triple quadrupole mass spectrometers 11 00:01:01,853 --> 00:01:07,804 this online SPE solution takes you into a new dimension of ultra low level detection 12 00:01:07,972 --> 00:01:11,038 with straightforward, turn-key operation. 13 00:01:12,041 --> 00:01:19,185 An extensive portfolio of valves makes it easy to customize your online SPE system to fit your needs. 14 00:01:19,250 --> 00:01:24,150 Combine these kits with the SPE starter set for applications such as: 15 00:01:24,248 --> 00:01:25,466 Direct injection 16 00:01:25,501 --> 00:01:27,313 Multi-SPE 17 00:01:27,348 --> 00:01:30,542 High volume injection, or Flask sampling 18 00:01:30,577 --> 00:01:37,613 The starter set opens the door to endless online SPE possibilities with a 2-position/10-port valve 19 00:01:37,648 --> 00:01:42,645 mounted in the Flexible Cube and connected to two SPE cartridges. 20 00:01:43,286 --> 00:01:47,452 The Flexible Cube's built-in piston pump and solvent selection valve 21 00:01:47,487 --> 00:01:51,568 allow you to condition the first cartridge with up to three different solvents. 22 00:01:51,603 --> 00:01:56,194 In parallel, the second cartridge is in the analytical flow path. 23 00:01:56,229 --> 00:02:03,374 After injection, the piston pump is used to deliver up to 1.8 milliliters of sample onto the SPE cartridge 24 00:02:03,409 --> 00:02:10,000 to enrich the analytes of interest while the matrix constituents such as salt are flushed to waste. 25 00:02:14,480 --> 00:02:20,618 When the sample has been loaded, the 2-position/10-port valve switches to the "elute" position 26 00:02:20,653 --> 00:02:25,119 and the LC pump extracts the enriched analytes from the SPE cartridge 27 00:02:25,200 --> 00:02:32,466 for separation on the analytical column and detection with the triple quadrupole mass spectrometer. 28 00:02:37,972 --> 00:02:45,141 Expand your application possibilities further by adding the Direct Injection Kit to your SPE Starter Set. 29 00:02:45,176 --> 00:02:50,750 This kit includes an additional 2-position/10-port valve so that your system can now 30 00:02:50,780 --> 00:02:56,650 alternate between online SPE and direct injection onto the analytical column. 31 00:02:56,700 --> 00:03:02,739 This configuration gives you the flexibility to run calibration standards or check system performance 32 00:03:02,750 --> 00:03:07,520 in direct injection mode - without the SPE cartridge in the flow path, 33 00:03:07,550 --> 00:03:13,108 and without the need to change plumbing or valves, or even switch to a different LC/MS system. 34 00:03:13,143 --> 00:03:18,261 Switching the additional valve takes you back to online SPE mode. 35 00:03:21,924 --> 00:03:26,811 You can now inject your sample and enrich the analytes of interest on the SPE cartridge, 36 00:03:26,846 --> 00:03:29,843 and flush the matrix constituents to waste. 37 00:03:30,479 --> 00:03:34,830 When the sample has been loaded, the valve is switched to the "elute" position 38 00:03:34,865 --> 00:03:39,062 and the enriched analytes are extracted for separation on the analytical column 39 00:03:39,097 --> 00:03:42,959 and detection with the triple quadrupole mass spectrometer. 40 00:03:46,066 --> 00:03:53,173 Agilent 1200 Infinity Series Online SPE solutions boost productivity of your laboratory 41 00:03:53,250 --> 00:03:56,317 by saving time and reducing costs. 42 00:03:57,434 --> 00:04:01,689 While advanced valve solutions give you the utmost automation flexibility 43 00:04:01,724 --> 00:04:04,625 to address even the most challenging applications, 44 00:04:05,000 --> 00:04:12,650 Agilent's triple quadrupole mass spectrometers deliver unmatched sensitivity and quantitative performance. 45 00:04:18,200 --> 00:04:24,824 Flexible Online SPE is just one of a wave of innovative technologies to ensure your 46 00:04:24,859 --> 00:04:30,750 Agilent LC and LC/MS solutions stay at the forefront of separation potential.